HA System Switch Over Alarm
This alarm is applicable only to products supporting HA (Mediant 500, Mediant 800, Mediant 2600, Mediant 4000, Mediant 9000, and Mediant Software).
acHASystemSwitchOverAlarm
Alarm |
acHASystemSwitchOverAlarm |
||
---|---|---|---|
OID |
1.3.6.1.4.1.5003.9.10.1.21.2.0.35 |
||
Description |
The alarm is sent when a switchover occurs from active to redundant device in a High Availability (HA) system. |
||
Default Severity |
Critical |
||
Source Varbind Text |
System#0/Module#<m>, where m is the blade module’s slot number |
||
Event Type |
qualityOfServiceAlarm |
||
Probable Cause |
outOfService |
||
Severity |
Condition |
Text |
Corrective Action |
Critical |
A switchover from the active to the redundant unit has occurred |
(See acHASystemFaultAlarm) |
See HA System Configuration Mismatch Alarm for details. |
A switchover occurred due to the HA Network Monitor feature as the threshold of unreachable rows (in the HA Network Monitor table) was exceeded. The indices of these unreachable rows are provided in the alarm's text. |
"Reason = Network Monitor error. Failed table rows index: <id 1> … up to <id 10>" |
|
|
Cleared |
10 seconds have passed since the switchover |
- |
- |